GammaCam LT27 - Technology to Enhance Worker Safety

Nuclear Detection System - Portable Gamma Ray Imaging System - EDO's GammaCamEDO's GammaCam represents a completely new dimension in assessing nuclear radiation fields by producing accurate two-dimensional images of gamma ray emitting objects. The portable system provides real-time pseudo-color gamma ray imagery superimposed on a conventional black and white video picture. Remote operation of the sensor head allows safe acquisition of gamma ray images in high radiation environments while minimizing worker exposure.

Sales and leases to both the Department of Energy (DoE) and commercial nuclear facilities demonstrate that the GammaCam is a useful tool in identifying gamma radiation sources and reducing exposure to personnel. The recorded gamma ray images can be used in multiple applications including survey management, job planning, inspection, and shielding evaluation. In addition to being a valuable ALARA tool, GammaCam improves the initial site characterization of Decontamination and Decommissioning job sites and characterization of unknown sources. By identifying the highest gamma radiation sources, the GammaCam provides valuable dose reduction information. Before and after images captured by the GammaCam are a useful tool in validating gamma radiation source elimination.

GammaCam Applications

Commercial Nuclear Power Plants

Homeland Security - Nuclear Material Control

Decontamination and Decommissioning (Site Cleanup) - Environmental Restoration Applications

Nuclear Navy

Public Health

GammaCam Model LT27 Sensor Module Specifications

Spectral Range

< 50 keV to > 1.5 MeV

Detector

High density terbium-activated scintillating glass

Sensitivity

1 µR integrated dose for Cs-137 point source and 7:1 SNR (6 µR/hr above background at sensor head)

Exposure Time

User selectable, 1 millisecond - 10 minutes, Software Summing for >10 minutes

Field of View (FOV)

25 degrees Narrow FOV Mode, 50 degrees Wide FOV Mode

Spatial Resolution

1.3 degrees Narrow FOV Mode, 2.6 degrees Wide FOV Mode

Dynamic Range

Instrument: >10E8,
Single Image: >20:1

Color or B&W Video FOV

73 degrees Horizontal, 55 degrees Vertical

Temperature

Operation: 5 degrees C - 40 degrees C,
Storage: -20 degrees C- 50 degrees C

Humidity

0 - 99% noncondensing

Detection Head

Weight: 45 Pounds,
Size: 20 in. Length,
10 in. Width,
10 in. Height,
Tripod Mountable

Processor (Optional)

Rugged Laptop Computer (IBM PC Compatible), Intel Pentium CPU, 256 Megabytes RAM (min), Active Matrix LCD Color Display, Internal Hard Drive, CD-RW

Standard Software

GammaSoft™

System Power

120 Watts, 110 - 240 VAC 50/60 Hz